16-8. Weld commandsPowder plasma welding
16-8-1. ARC-SET_POWD
Format
ARC-SET_POWD Ib= [Base amp] Ip= [Peak amp] PF= [Powder] FRQ= [Freq] S= [Speed]
Function It sets a powder plasma welding condition.
Condition
Base amp Welding amperage or base
amperage at pulsed welding
[5 - 200] A
Lock condition Arc lock (Internal execution).
Syntax check None.
Peak amp No designation at no-pulsed
welding.
Peak amperage at pulsed welding
[5 - 200] A
Powder Powder feed [0, 14 - 100]
Freq Pulse frequency [0.5 - 25.0] Hz
Example
Set the base amp to20Athe peak amp to 95A
the powder to 38the pulse frequency to 6.0Hz
and the weld speed to 0.26m/min.
ARC-SET_POWD Ib=20 Ip=95 PF=38 FRQ=6.0
S=0.26
Speed Weld speed [0.01 - 120.00] m/min
16-8-2. CARRYGAS
Format
CARRYGAS [ON/OFF]
Function It turns on or off the carrier gas. ON/OFF Carrier gas control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the carrier gas.
CARRYGAS ON
The same command in
conventional models
16-8-3. CRATER_POWD
Format
CRATER_POWD Ib= [Base amp] Ip= [Peak amp] PF= [Powder] FRQ= [Freq] T= [Time]
Function It sets a crater filler welding condition.
Condition
Base amp Welding amperage or base
amperage at pulsed welding
[5 - 200] A
Lock condition Arc lock (Internal execution).
Syntax check None.
Peak amp No designation at no-pulsed
welding.
Peak amperage at pulsed welding
[5 - 200] A
Powder Powder feed [0, 14 - 100]
Freq Pulse frequency [0.5 - 25.0] Hz
Example Set the base amperage to 15A, the peak
amperage to 75A, the powder to 38, the
frequency to 6.0Hz and the time to 0.50s.
CRATER_POWD Ib=15 Ip=75 PF=38 FRQ=6.0
T=0.50
Time
welding time0.00 - 99.99
16-8-4. F-RANGE
Format
F-RANGE = [High / Low]
Function It changes the frequency range. High / Low Frequency range selection
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Change the frequency range to the high.
F-RANGE High
The same command in
conventional models