16-8-14. SHLDGAS
Format
SHLDGAS [ON/OFF]
Function It turns on or off the shield gas. ON/OFF Shield gas control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the shield gas.
SH
LDGAS ON
The same command in
conventional models
16-8-15. STARTGAS
Format
STARTGAS [ON/OFF]
Function It turns on or off the start gas. ON/OFF Start gas control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the start gas.
STARTGAS ON
The same command in
conventional models
16-8-16. WAIT-PLARC
Format
WAIT-PLARC
Function It waits pilot arc. Non
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Wait by starting pilot arc.
WAITPLARC
The same command in
conventional models
16-8-17. WPLS_PWD
Format
WPLS_PWD [ON/OFF]
Function It turns on or off welding pulse control. ON/OFF Pulse control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the pulse.
WPLS_PWD ON
The same command in
conventional models