16-22
16-5-33. TORCHSW
Format
TORCHSW
Function It turns ON or OFF the torch switch. ON/OFF ON: to turn ON the torch switch.
Condition Weld package. OFF: to turn OFF the torch switch.
Lock condition Arc lock.
Syntax check None.
Example Turn ON the torch switch.
TORCHSW ON
The same command in
conventional models
OUTB OPORT#209=*
16-5-34. TSO
Format
TSO [Value]
Function It adjusts initial short time. Value
Adjustment value [−3 - +3]
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Set the initial short time to +1.
TSO +1
The same command in
conventional models
16-5-35. TSP
Format
TSP [Value]
Function It adjusts wire sticking prevention time. Value
Adjustment value [−3 - +3]
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Adjust the wire sticking prevention time to +1.
TSP +1
The same command in
conventional models
16-5-36. VOLT
Format
VOLT [Voltage]
Function It sets welding voltage. Voltage
Condition Weld package.
Welding voltage.
[0.1 - 99.9] V
Lock condition Arc lock (Internal execution, set values).
Syntax check None.
Example Set welding voltage to 24 V.
VOLT=24
The same command in
conventional models
VOLT
16-5-37. WAIT-ARC
Format
WAIT-ARC
Function It stops operation of the mechanism until arc generation is detected (detects welding current).
Condition Weld package
Lock condition Arc lock
Syntax check None
Example
WAITARC
The same command in
conventional models
WAIT IPORT#217=1