EasyManua.ls Logo

Renesas RL78/G10 - Page 504

Renesas RL78/G10
637 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RL78/G10 CHAPTER 13 SERIAL INTERFACE IICA
R01UH0384EJ0311 Rev. 3.11 487
Dec 22, 2016
Figure 13-31. Example of Master to Slave Communication
(9-Clock Wait Is Selected for Master, 9-Clock Wait Is Selected for Slave) (4/4)
(4) Data ~ restart condition ~ address
L
H
L
H
L
H
IICA0
STT0
(ST trigger)
SPT0
(SP trigger)
ACKD0
(ACK detection)
WTIM0
(8 or 9 clock wait)
ACKE0
(ACK control)
MSTS0
(communication status)
TRC0
(transmit/receive)
SCLA0 (bus)
(clock line)
WREL0
(wait cancellation)
INTIICA0
(interrupt)
SDAA0 (bus)
(data line)
AD6
IICA0
STD0
(ST detection)
SPD0
(SP detection)
ACKD0
(ACK detection)
WTIM0
(8 or 9 clock wait)
ACKE0
(ACK control)
MSTS0
(communication status)
TRC0
(transmit/receive)
WREL0
(wait cancellation)
INTIICA0
(interrupt)
Master side
Bus line
Slave side
Slave address
D
1
3
ACK
<i>
L
H
H
L
H
Restart condition
D
1
2 D
1
1 D
1
0
AD5 AD4 AD3 AD2
AD1
<ii>
<iii>
<7>
<8>
Note 2
Note 1
: Wait state by master device
: Wait state by slave device
: Wait state by master and slave devices
Notes 1. Make sure that the time between the rise of the SCLA0 pin signal and the generation of the start
condition after a restart condition has been issued is at least 4.7
μ
s when specifying standard mode and
at least 0.6
μ
s when specifying fast mode.
2. For releasing wait state during reception of a slave device, write “FFH” to IICA0 or set the WREL0 bit.

Table of Contents