CMU RF Measurements
1100.4903.12 6.63 E-10
Symbolic Status Event Register Evaluation
The following commands are used to retrieve the events reported in function group RF; see section
Symbolic Status Event Register Evaluation in chapter 5.
STATus:OPERation:SYMBolic:ENABle <Event>{,<Event>} Symbolic status evaluation
Parameter list
Parameter description
Def. Value
7
Default Unit FW vers.
<Event>{,<Event>} |
NONE
List of symbols for events to be reported
No event reported
NONE – V3.05
Command description
This command enables event reporting for one or several events in the RF function group, i.e. it sets the corre-
sponding bits in the STATus:OPERation:CMU: SUM<nr>:CMU<nr_event>:ENABle register (<nr> = 1 |
2, <nr_event> denotes the RF function group) and in all sum registers up to the status byte. The events and
the corresponding symbols for function group RF are listed in Chapter 5 (see section Status Registers). The
symbols may be entered in arbitrary order.
STATus:OPERation:SYMBolic[:EVENt]? Symbolic status evaluation
Response
Parameter description
Def. Value
8
Default Unit FW vers.
NONE |
<Event>{,<Event>}
No event in the RF function group
List of reported events
NONE – V3.05
Command description
This command is always a query. It lists the events reported in the RF function group and deletes these events in
the STATus:OPERation:CMU:SUM<nr> :CMU<nr_event>:EVENt register as well as in all sum registers.
7
The default values quoted in this command are achieved after a STATus:PRESet command. *RST does not supersede the entries in the status registers; see section
Reset Values of the Status Reporting Systems in chapter 5.
8
The default values quoted in this command are achieved after a *CLS command. *RST does not supersede the entries in the status registers; see section Reset Values of
the Status Reporting Systems in chapter 5.