1100.4903.12 6.96 E-10
Command Parameters Remarks Page
SAMPle:SUBarrays:SPECtrum[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.56
System STATus (status reporting system)
STATus:OPERation:SYMBolic[:EVENt]? NONE | <Event>{,<Event>} query only 6.63
STATus:OPERation:SYMBolic:ENABle <Event>{,<Event>} with query 6.63
Subsystem TRIGger
TRIGger[:SEQuence]:DEFault ON | OFF with query 6.29
TRIGger[:SEQuence]:SLOPe POSitive | NEGative with query 6.28
TRIGger[:SEQuence]:SOURce IMMediate | RFPower |
IFPower | EXTern
with query 6.28
TRIGger[:SEQuence]:SOURce:EXTernal PIN6 | PIN7 | PIN8 with query 6.29
TRIGger[:SEQuence]:THReshold:IFPower <Threshold> with query 6.28
TRIGger[:SEQuence]:THReshold:RFPower LOW | MEDium | HIGH with query 6.28
TRIGger[:SEQuence]:DEFault ON | OFF with query 6.31
TRIGger[:SEQuence]:SLOPe POSitive | NEGative with query 6.30
TRIGger[:SEQuence]:SOURce IMMediate | RFPower |
IFPower | EXTern
with query 6.30
TRIGger[:SEQuence]:SOURce:EXTernal PIN6 | PIN7 | PIN8 with query 6.31
TRIGger[:SEQuence]:THReshold:IFPower <Threshold> with query 6.30
TRIGger[:SEQuence]:THReshold:RFPower LOW | MEDium | HIGH with query 6.30
Subsystem WPOWer (wideband power)
INITiate:WPOWer – no query 6.57
ABORt:WPOWer – no query 6.57
STOP:WPOWer – no query 6.57
CONTinue:WPOWer – no query 6.57
CONFigure:WPOWer:CONTrol:REPetition CONTinuous | SINGleshot | 1
... 10000, SONerror |
NONE,STEP | NONE
with query 6.58
CONFigure:WPOWer:EREPorting SRQ | SOPC | SRSQ | OFF with query 6.57
FETCh:WPOWer:STATus? OFF | RUN | STOP | ERR |
STEP | RDY, 1 ... 10000 |
NONE
query only 6.57
READ[:SCALar]:WPOWer? <Result> query only 6.58
FETCh[:SCALar]:WPOWer? <Result> query only 6.58
SAMPle[:SCALar]:WPOWer? <Result> query only 6.58
Table 6-3 List of remote-control commands: Audio Measurements
Command Parameters Remarks Page
Subsystem AFANalyzer
INITiate:AFANalyzer:SECondary – no query 6.68
STOP:AFANalyzer:SECondary – no query 6.68
STOP:AFANalyzer:SECondary – no query 6.68
ABORt:AFANalyzer:SECondary – no query 6.68
CONTinue:AFANalyzer:SECondary – no query 6.68

Table of Contents

Other manuals for Rohde & Schwarz CMU 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz CMU 200 and is the answer not in the manual?

Rohde & Schwarz CMU 200 Specifications

General IconGeneral
BrandRohde & Schwarz
ModelCMU 200
CategoryTest Equipment
LanguageEnglish

Related product manuals