EasyManuals Logo

Rohde & Schwarz CMU 200 User Manual

Rohde & Schwarz CMU 200
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #361 background imageLoading...
Page #361 background image
CMU List of Commands
1100.4903.12 6.95 E-10
Command Parameters Remarks Page
| MAXimum |
IVAL,<Start>,<Samples>{,<St
art>,<Samples>}
READ:ARRay:SPECtrum:AVERage? –128.0 dBm to +48.0 dBm query only 6.55
FETCh:ARRay:SPECtrum:AVERage? –128.0 dBm to +48.0 dBm query only 6.55
SAMPle:ARRay:SPECtrum:AVERage? –128.0 dBm to +48.0 dBm query only 6.55
READ:SUBarrays:SPECtrum:AVERage? –128.0 dBm to +48.0 dBm query only 6.56
FETCh:SUBarrays:SPECtrum:AVERage? –128.0 dBm to +48.0 dBm query only 6.56
SAMPle:SUBarrays:SPECtrum:AVERage? –128.0 dBm to +48.0 dBm query only 6.56
CONFigure:SPECtrum:CONTrol SCALar | ARRay, 1 to 1000 |
NONE
with query 6.52
CONFigure:SPECtrum:CONTrol:REPetition CONTinuous | SINGleshot | 1
to 10000, NONE, STEP |
NONE
with query 6.53
[SENSe:]SPECtrum:DETector PEAK | RMS with query 6.52
CONFigure:SPECtrum:EREPorting SRQ | SOPC | SRSQ | OFF with query 6.51
[SENSe:]SPECtrum:FREQuency:BANDwidth[:RESolution] 10 Hz to 1 MHz | AUTO with query 6.53
[SENSe:]SPECtrum:FREQuency:BWIDth[:RESolution] 10 Hz to 1 MHz | AUTO with query 6.53
[SENSe:]SPECtrum:FREQuency:CENTer 10.000005 MHz to
2.699999995 GHz
with query 6.53
[SENSe:]SPECtrum:FREQuency:SPAN 0.00001 MHz to 2.69999999
GHz
with query 6.53
[SENSe:]SPECtrum:FREQuency:STARt 10 MHz to 2.69999999 GHz with query 6.53
[SENSe:]SPECtrum:FREQuency:STOP 10.00001 MHz to 2.7 GHz with query 6.53
[SENSe:]SPECtrum:LEVel:RANGe 10 dB to 100 dB with query 6.54
READ:ARRay:SPECtrum:MAXimum? –128.0 dBm to +48.0 dBm query only 6.55
FETCh:ARRay:SPECtrum:MAXimum? –128.0 dBm to +48.0 dBm query only 6.55
SAMPle:ARRay:SPECtrum:MAXimum? –128.0 dBm to +48.0 dBm query only 6.55
READ:SUBarrays:SPECtrum:MAXimum? –128.0 dBm to +48.0 dBm query only 6.56
FETCh:SUBarrays:SPECtrum:MAXimum? –128.0 dBm to +48.0 dBm query only 6.56
SAMPle:SUBarrays:SPECtrum:MAXimum? –128.0 dBm to +48.0 dBm query only 6.56
READ:ARRay:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.55
READ:ARRay:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.55
FETCh:ARRay:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.55
FETCh:ARRay:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.55
SAMPle:ARRay:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.55
READ:SUBarrays:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.56
READ:SUBarrays:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.56
FETCh:SUBarrays:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.56
FETCh:SUBarrays:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.56
SAMPle:SUBarrays:SPECtrum:MINimum? –128.0 dBm to +48.0 dBm query only 6.56
FETCh:SPECtrum:STATus? OFF | RUN | STOP | ERR |
STEP | RDY, 0 to 10000 |
NONE , 0 to 1000 | NONE
query only 6.51
READ:ARRay:SPECtrum[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.55
FETCh:ARRay:SPECtrum[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.55
SAMPle:ARRay:SPECtrum[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.55
READ:SUBarrays:SPECtrum[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.56
FETCh:SUBarrays:SPECtrum[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.56

Table of Contents

Other manuals for Rohde & Schwarz CMU 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz CMU 200 and is the answer not in the manual?

Rohde & Schwarz CMU 200 Specifications

General IconGeneral
BrandRohde & Schwarz
ModelCMU 200
CategoryTest Equipment
LanguageEnglish

Related product manuals