CMU Audio Generator and Analyzer (with Option CMU-B41)
1100.4903.12 6.69 E-10
CONFigure:AFANalyzer[:PRIMary]:MTReduce <Mode>, <Frequency> Reduce Measurement Time
CONFigure:AFANalyzer:SECondary:MTReduce
<Mode>
Description of parameters Def. value Def. unit
LOWF |
EXPF
Measurement time according to lowest frequency (10
kHz)
Measurement time according to <Frequency>
LOWF
<Frequency>
Description of parameters Def. value Def. unit FW vers.
10 Hz to 20 kHz Expected frequency of the audio input signal 100 Hz V3.0
Description of command
This command is to reduce the measurement time the audio analyzer uses to calculate the measurement results
(<Mode>=EXPF); see section Subsystem AFANalyzer... (Measured Values) on page 6.73. The measurement
time must be adapted to the period of the input signal, which is the reverse of the frequency. Therefore, the audio
measurement can be accelerated for high-frequency signals. In the LOWF mode, <Frequency> is not taken into
account.
Subsystem AFANalyzer...:CONTrol (Control)
The subsystem AFANalyzer:...CONTrol defines the scope of the audio analysis and sets the reference
frequency for the distortion measurement. The settings are provided in the Control and Distortion tabs
of the Analyzer Configuration popup menu.
CONFigure:AFANalyzer[:PRIMary]:CONTrol:REPetition Test Cycles
CONFigure:AFANalyzer:SECondary:CONTrol:REPetition
<Repetition>, <StopCondition>, <Stepmode>
<Repetition>
Description of parameters Def. value Def. unit
CONTinuous |
SINGleshot |
1 to 10000
Continuous measurement (until STOP or ABORt)
Single shot measurement (until Status = RDY)
Multiple measurement (counting, until Status =
STEP | RDY)
SING –
<StopCondition>
Description of parameters Def. value Def. unit
NONE Continue measurement even in case of error NONE –
<Stepmode>
Description of parameters Def. value Def. unit FW vers.
STEP |
NONE
Interrupt measurement after each statistic cycle Con-
tinue measurement according to its rep. mode
NONE – V2.10
Description of command
This command determines the number of statistics cycles and the stepping mode for the measurement. A stop
condition is not available.
Note: In the case of READ commands (READ: to) the <Repetition> parameter has no effect; the measure-
ment is always stopped after a single shot.