EasyManua.ls Logo

Rohde & Schwarz CMU 200 - Page 364

Rohde & Schwarz CMU 200
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Commands CMU
1100.4903.12 6.98 E-10
Command Parameters Remarks Page
INITiate:AFGenerator[:PRIMary] – no query 6.73
ABORt:AFGenerator[:PRIMary] – no query 6.73
SOURce:AFGenerator[:PRIMary]:FREQuency 20 Hz to 20 kHz with query 6.74
SOURce:AFGenerator[:PRIMary]:LEVel
0 µV to 5 V
with query 6.74
SOURce:AFGenerator[:PRIMary]:SMODe 20 Hz to 20 kHz with query 6.74
FETCh:AFGenerator[:PRIMary]:STATus? OFF | RUN | ERR query only 6.74
Subsystem AFLevel (AF input level)
[SENSe:]AFLevel:DEFault ON | OFF with query 6.67
[SENSe:]AFLevel:SECondary:MAXimum <Level> with query 6.67
[SENSe:]AFLevel:SECondary:MODE MANual | AUTO with query 6.66
[SENSe:]AFLevel[:PRIMary]:MAXimum <Level> with query 6.67
[SENSe:]AFLevel[:PRIMary]:MODE MANual | AUTO with query 6.66
Save/Recall of settings
MMEMory:RECall:CURRent <FileName> [,<msus>] no query 6.65
MMEMory:SAVE:CURRent <FileName> [,<msus>] no query 6.66
Subsystem MULTitone
INITiate:MULTitone:AF1Channel – no query 6.75
ABORt:MULTitone:AF1Channel – no query 6.75
STOP:MULTitone:AF1Channel – no query 6.75
CONTinue:MULTitone:AF1Channel – no query 6.75
CONFigure:SUBarrays:MULTitone:AF1Channel ALL | ARITHmetical |
MINimum | MAXimum |
IVAL,<Range>{,<Range>}
with query 6.78
CONFigure:MULTitone:AF1Channel:AFGLead 0 s to 0.1 s with query 6.77
CONFigure:MULTitone:AF1Channel:CONTrol AC | DC with query 6.76
CONFigure:MULTitone:AF1Channel:CONTrol:REPetition CONTinuous | SINGleshot | 1
to 1000, SONerror | NONE,
STEP | NONE
with query 6.77
CONFigure:MULTitone:AF1Channel:EREPorting SRQ | SOPC | SRSQ | OFF with query 6.75
DEFault:MULTitone:AF1Channel:FILTer ON | OFF with query 6.85
CONFigure:MULTitone:AF1Channel:FILTer:BPASs:ACCoupling <Bandpass> with query 6.84
CONFigure:MULTitone:AF1Channel:FILTer:BPASs:DCCoupling <Bandpass> with query 6.84
CONFigure:MULTitone:AF1Channel:FILTer:WEIGhting <Weighting> with query 6.85
DISPlay:MULTitone:AF1Channel:GRID ON | OFF with query 6.76
DEFault:MULTitone:AF1Channel:LIMit:LINE ON | OFF with query 6.80
CONFigure:MULTitone:AF1Channel:LIMit:LINE:ASYMmetric
:LOWer
<Limit_1>, <Enable_1>, ...
<Limit_20>, <Enable_20>
with query 6.80
CONFigure:MULTitone:AF1Channel:LIMit:LINE:ASYMmetric
:UPPer
<Limit_1>, <Enable_1>, ...
<Limit_20>, <Enable_20>
with query 6.79
CALCulate[:SCALar]:MULTitone:AF1Channel:MATChing:LIMit? <Result> query only 6.87
CALCulate:ARRay:MULTitone:AF1Channel:MATChing:LIMit? <Result> query only 6.88
CONFigure:MULTitone:AF1Channel:RLEVel 0.001 V to 5.000 V with query 6.76
CONFigure:MULTitone:AF1Channel:RMODe RLEV | TON1 | ... | TON20 with query 6.77
FETCh:MULTitone:AF1Channel:STATus? OFF | RUN | STOP | ERR |
STEP | RDY, 1 to 10000 |
NONE
query only 6.76
CONFigure:MULTitone:AF1Channel:TDEFinition <Freq_1>, <Lev_1>, with query 6.81

Table of Contents

Other manuals for Rohde & Schwarz CMU 200

Related product manuals