Reset and clock control (RCC) RM0401
94/771 RM0401 Rev 3
Each clock source can be switched on or off independently when it is not used, to optimize
power consumption.
Figure 12. Clock tree
1. For full details about the internal and external clock source characteristics, refer to the Electrical
characteristics section in the device datasheet.
06Y9
$+%
35(6&
LI$3%[SUHVF [
HOVH[
/6(
)&/.&RUWH[
IUHHUXQQLQJFORFN
$3%[FORFNV
$3%[
WLPHUFORFNV
51*
0&2
3HULSKHUDO
FORFNHQDEOH
0&2
26&B287
/6(26&
N+]
/6,5&
N+]
WR
LQGHSHQGHQW
ZDWFKGRJ
/6(
/6,
WR57&
57&&/.
57&6(/>@
,:'*&/.
26&B,1
26&B287
3//&/.
+6,
+6,
+6(
6:
6<6&/.
0+]
PD[
+&/.
WR$+%EXVFRUH
0HPRU\DQG'0$
0+]PD[
WR&RUWH[6\VWHPWLPHU
&ORFN
(QDEOH
51*
FORFNHQDEOH
$3%[
35(6&
:DWFKGRJ
HQDEOH
57&
HQDEOH
WR
6<6&/.
+6(B57&
+6(
,6B&.,1
26&B,1
3HULSKHUDO
FORFNHQDEOH
3//
[1
3
4
5
9&2
0
0+]
+6,5&
WR
WR
0+]
+6(26&
,6BFN
3//&/.B5
(QDEOHGLI63,,663,,6
RU63,,6DUHHQDEOHG
,665&
,6BFN
,6FORFN
,6BFN
HQDEOH
+6,
6<6&/.
&.B$3%
'&.&)*5
,&)0FORFN
,&BFNB
HQDEOH
/6,
+6,
&.B$3%B7,0
'&.&)*5
/37,0FORFN
/37,0BFNB
HQDEOH
/6(