PTO Speed Display Mode Switching (Setting Mode)
1. While pressing the PTO/Hour meter select switch (1), turn the
key switch to "ON" position.
The current numerical code starts flashing.
2. Each time the PTO/Hour meter select switch (1) is pressed, the
code changes in the order of [1] → [2] → [1]. Select the
appropriate code according to the table below.
3. Press and hold the PTO/Hour meter select switch (1) longer
than 2 seconds. The setting is put in memory, and the LCD
monitor (2) goes back to the PTO speed display mode.
4. Turn the key switch to "OFF" position to exit.
• The setting will be cancelled if the key switch is turned OFF
halfway in the procedure.
9Y1210143ELS0035US0
Numerical code PTO speed (min
-1
(rpm))
1
540 (Single speed)
540 / 540E (2 speed PTO gear shift type)
2 540 / 1000 (2 speed PTO gear shift type)
(1) PTO/Hour Meter Select Switch
(2) LCD Monitor
(A) Procedure to enter the PTO
speed display mode switching
(B) Procedure to select numerical
code