4-36 Xerox Internal Use Only Phaser 6000/6010 and WC 6015 MFP
Troubleshooting
CRUM M Sensor (DI-9) Magenta CRUM Sensor
CRUM C Sensor (DI-a) Cyan CRUM Sensor
CRUM K Sensor (DI-b) Black CRUM Sensor
Motor Test These tests check operation of the electromechanical components.
Press the OK button to run the selected test. Press Stop to exit the
test. The display returns to the Service Mode menu.
NOTE During the Motor Tests, no other diagnostic functions can be performed. The
printer only accepts component and exit commands.
Component Tests
Test: Code Component
Main Motor (FULL): D0-0
Main Motor (HALF): D0-1
Main Motor (SLOW): D0-2
Main Drive Assembly
Caution: When checking the Main
Motor, stop the test within
10 seconds. Executing this
test for 10 seconds or longer
may cause damage to the
printer.
Fan Motor (FULL): D0-4
Fan Motor (HALF): D0-5
Fan Motor
Caution: When checking the Fan
Motor, stop the test within
10 seconds. Executing this
test for more than 10
seconds may cause damage
to the printer.
Regi Clutch: D0-7 Drive Clutch
Feed SOLENOID: D0-9 Feed Solenoid
K Mode SOLENOID: D0-b Developer Drive Assembly
Yell ow Toner Motor: D0-1 0
Magenta Toner Motor: D0-12
Cyan Toner Motor: D0-14
Black Toner Motor: D0-16
Toner Motors
Caution: When checking the toner
motors, stop the test within
3 seconds. Executing this
test for more than 3 seconds
may cause damage to the
printer.
DBAC ON
NOTE The use of DBAC ON, DBDC ON, TR1+
ON, TR2+ ON, TR2- ON, CR ON, MOB
LED ON, ADC LED ON, 24V ON, HV CLK
ON is prohibited to avoid shock hazards
since they are high-voltage outputs.
DBDC ON
TR1+ ON
TR2+ ON
TR2- ON
CR ON
MOB LED ON
ADC LED ON
24V ON
HV CLK ON
NVM Settings Edits, saves, loads, and prints NVM information.
Edit NVM
â– Ad0000=00000000*
â– Please wait
Displays current NVM values. Use this
function to edit NVM information.
Caution: Change NVM values only
when directed to do so by a
troubleshooting procedure.
Save NVM to ESS Save NVM
â– Save NVM MCU -> ESS OK?
â– Saved
â– Please wait
Saves the MCU Board NVM to the IP
Board temporarily when the MCU
needs to be replaced.
Tes t
Control Panel
(WorkCentre 6015 MFP)
Test Description