Chapter 16 SCPI Command Reference
System commands
9102 Handheld Spectrum Analyzer Software version 5.31
267
:SYSTem:COMMunicate:ETHernet:TERMinator
:SYSTem:COMMunicate:SER:BAUDrate
:SYSTem:COMMunicate:SER:TERMinator
Query
Reads and returns the current setting of the port used by TCPIP as
explained above.
Example
SYST:COMM:ETHernet:PORT 49200 sets the TCP/IP port address to its
default.
Syntax
:SYSTem:COMMunicate:ETHernet:TERMinator <PredefExpr>
Parameters
PredefExpr is one of the following predefined expressions:
CRLF|LF|CR.
Default is CRLF.
Command
Sets the terminator characters, which are appended to every SCPI respond
from the Aeroflex 9102 LAN interface.
Query
Reads and returns the current terminator setting for the LAN interface.
Example
:SYST:COMM:ETH:TERM CR
:SYST:COMM:ETH:TERM?
Returns the following string: "CR"
Syntax
:SYSTem:COMMunicate:SER:BAUDrate <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 300, the maximum value is 57600. The
default value for int1 is 57600. Valid values are
300,1200,2400,4800,9600,19200,38400 and 57600.
Command
Sets the data rate for the serial port. Only the data rate can be changed; all
other parameters are fixed. The number of bits per character is set to 8, the
number of stop bits is set to 1 and parity is set to NO.
Query
Reads and returns the serial interface data rate currently set.
Example
:SYST:COMM:SER:BAUD 9600
:SYST:COMM:SER:BAUD?
String returned in this example: "9600".
Syntax
:SYSTem:COMMunicate:SER:TERMinator <PredefExpr>
Parameters
PredefExpr is one of the following predefined expressions:
CRLF|LF|CR.
Default is CRLF.
Command
Sets the terminator characters, which are appended to every SCPI
response from the Aeroflex 9102 serial interface.
Query
Reads and returns the current terminator setting for the serial interface.
Example
:SYST:COMM:SER:TERM LF
:SYST:COMM:SER:TERM?
Returns the following string: "LF"