Parameter Description
address.
The valid value is 0 to 100000, where 0 means that login is
not denied regardless of number of failed login attempts.
The default is 60.
Display Last Login Information
[DisplayLoginInformation]
Enables display of user's login information on each
successful login attempt.
[0] Disable (default)
[1] Enable
[EnableMgmtTwoFactorAuthentication]
Enables Web login authentication using a third-party, smart
card.
[0] = Disable (default)
[1] = Enable
When enabled, the device retrieves the Web user’s login
username from the smart card, which is automatically
displayed (read-only) in the Web Login screen; the user is
then required to provide only the login password.
Typically, a TLS connection is established between the
smart card and the device’s Web interface, and a RADIUS
server is
implemented to authenticate the password with the
username. Thus, this feature implements a two-factor
authentication - what the user has (the physical card) and
what the user knows (i.e., the login password).
http-port
[HTTPport]
Defines the LAN HTTP port for Web management. To
enable Web management from the LAN, configure the
desired port.
The default is 80.
Note: For the parameter to take effect, a device reset is
required.
[DisableWebConfig] Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified and
the following pages can't be accessed: Web User Accounts,
TLS Contexts, Time and Date, Maintenance Actions, Load
Auxiliary Files, Software Upgrade Wizard, and Configuration
File.
Note: For the parameter to take effect, a device reset is
required.
[ResetWebPassword] Enables the device to restore the default management
users:
Security Administrator user (username "Admin";
password "Admin")
Monitor user (username "User"; password "User")
In addition, all other users that may have been configured
(in the Local Users table) are deleted.
[0] = (Default) Disabled. Currently configured users
(usernames and passwords) are retained.
[1] = Enabled. Default users are restored (see
description above) and all other configured users are

Table of Contents