Version 7.2 1231 Mediant 800B Gateway & E-SBC
User's Manual 72. Configuration Parameters Reference
Parameter Description
all ETSI-like standards.
[64] USE T1 PRI = PRI interface type is forced to T1.
[128] USE E1 PRI = PRI interface type is forced to E1.
[256] START WITH B CHAN OOS = B-channels start in the
Out-Of-Service state (OOS).
[512] CHAN ALLOC LOWEST = CC allocates B-channels
starting from the lowest available B-channel id.
[1024] CHAN ALLOC HIGHEST = CC allocates B-channels
starting from the highest available B-channel id.
[16384] CC_TRANSPARENT_UUI bit: The UUI-protocol
implementation of CC is disabled allowing the application to
freely send UUI elements in any primitive, regardless of the
UUI-protocol requirements (UUI Implicit Service 1). This
allows more flexible application control on the UUI. When
this bit is not set (default behavior), CC implements the
UUI-protocol as specified in the ETS 300-403 standards for
Implicit Service 1.
[65536] GTD5 TBCT = CC implements the VERIZON-GTD-
5 Switch variant of the TBCT Supplementary Service, as
specified in FSD 01-02-40AG Feature Specification
Document from Verizon. Otherwise, TBCT is implemented
as specified in GR-2865-CORE specification (default
behavior).
Note: When using the ini file to configure the device to support
several ISDNGeneralCCBehavior features, add the individual
feature values. For example, to support both [16] and [32]
features, set ISDNGeneralCCBehavior = 48 (i.e., 16 + 32).
Outgoing Calls Behavior
configure voip > interface e1-t1
bri > isdn-bits-outgoing-calls-
behavior
[ISDNOutCallsBehavior]
Determines several behaviour options (bit fields) that influence
the behaviour of the ISDN Stack outgoing calls. To select
options, click the arrow button, and then for each required
option, select 1 to enable. The default is 0 (i.e., disable).
[2] USER SENDING COMPLETE =The default behavior of
the device (when this bit is not set) is to automatically
generate the Sending-Complete IE in the Setup message.
This behavior is used when overlap dialing is not needed.
When overlap dialing is needed, set this bit and the
behavior is changed to suit the scenario, i.e., Sending-
Complete IE is added when required in the Setup message
for Enblock mode or in the last Digit with Overlap mode.
[16] USE MU LAW = The device sends G.711-m-Law in
outgoing voice calls. When disabled, the device sends
G.711-A-Law in outgoing voice calls.
Note: This option is applicable only to the Korean variant.
[128] DIAL WITH KEYPAD = The device uses the Keypad
IE to store the called number digits instead of the
CALLED_NB IE.
Note: This option is applicable only to the Korean variant
(Korean network). This is useful for Korean switches that
don't accept the CALLED_NB IE.
[256] STORE CHAN ID IN SETUP = The device forces the
sending of a Channel-Id IE in an outgoing Setup message
even if it's not required by the standard (i.e., optional) and