Version 7.2 289 Mediant 800B Gateway & E-SBC
User's Manual 15. Services
Trunk Group Availability: Status is reported when the trunk's physical state indicates
that the trunk is unavailable.
Configuration Status: Status is reported when IP Groups, Trunk Groups or SIP
Interfaces that are configured to be used by remote Web-based services (i.e., the
UsedByRoutingServer parameter is set to 1 - Used) are created or deleted. If you
subsequently change the settings of the UsedByRoutingServer parameter or the 'Name'
parameter, the device reports the change as a creation or deletion of the corresponding
configuration entity.
Capture: Recording of signaling and RTP packets, and Syslog. The remote host can be, for
example, a Syslog server or AudioCodes SEM.
QoS: Call routing based on QoS. For more information, see Configuring QoS-Based Routing
by Routing Server on page
297.
Note:
You can configure only one Remote Web Service for each of the following server types:
Routing, Call Status, Topology Status, and QoS.
The Routing service also includes the Call Status and Topology Status services.
You can configure up to four Remote Web Services for Capture. However, the Capture
service is currently not supported.
The device supports HTTP redirect responses (3xx) only during connection
establishment with the host. Upon receipt of a redirect response, the device attempts to
open a new socket with the host and if this is successful, closes the current connection.
The following procedure describes how to configure Remote Web Services through the Web
interface. You can also configure it through ini file (HTTPRemoteServices) or CLI (configure
system > http-services > http-remote-services).
To configure a remote Web service:
1. Open the Remote Web Services table (Setup menu > IP Network tab > Web Services
folder > Remote Web Services).
2. Click New; the following dialog box appears:
Figure 15-43: Remote Web Services Table - Add Dialog Box