User's Manual 80 Document #: LTRT-10632
Mediant 800B Gateway & E-SBC
Note:
For security, it's recommended that you change the default username and
password of the default users.
To restore the device to the default users (and with their default usernames and
passwords), configure the ini file ResetWebPassword parameter to 1. If you have
configured any other accounts, they are deleted.
If you delete a user who is currently in an active Web session, the user is
immediately logged off the device.
Up to five users can be concurrently logged in to the Web interface; they can all be
the same user.
You can set the entire Web interface to read-only (regardless of Web user access
levels), using the ini file parameter DisableWebConfig (see 'Web and Telnet
Parameters' on page 1055).
You can define additional Web user accounts using a RADIUS server (see
'RADIUS Authentication' on page 250).
The following procedure describes how to configure user accounts through the Web
interface. You can also configure it through ini file (WebUsers) or CLI (configure system >
user).
To configure management user accounts:
1. Open the Local Users table (Setup menu > Administration tab > Web & CLI folder >
Local Users).
2. Click New; the following dialog box is displayed:
Figure 6-30: Local Users Table - Dialog Box
3. Configure a user account according to the parameters described in the table below.
4. Click Apply, and then save your settings to flash memory.