Version 7.2 81 Mediant 800B Gateway & E-SBC
User's Manual 6. Web-Based Management
Table 6-7: Local Users Table Parameter Descriptions
Parameter Description
General
Index
[WebUsers_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Username
user
[WebUsers_Username]
Defines the Web user's username.
The valid value is a string of up to 40 alphanumeric characters,
including the period ".", underscore "_", and hyphen "-" signs.
Password
password
[WebUsers_Password]
Defines the Web user's password.
The valid value is a string of 8 to 40 ASCII characters. To ensure
strong passwords, adhere to the following password complexity
requirements:
Contain at least eight characters.
Contain at least two letters that are upper case (e.g., A).
Contain at least two letters that are lower case (e.g., a).
Contain at least two numbers (e.g., 4).
Contain at least two symbols (non-alphanumeric characters) (e.g.,
$, #, %).
No spaces.
Contain at least four new characters that were not used in the
previous password.
Note:
To enforce the password complexity requirements mentioned
above, configure the EnforcePasswordComplexity to 1.
For security, password characters are not shown in the Web
interface and ini file. In the Web interface, they are displayed as
dots when you enter the password and then once applied, the
password is displayed as an asterisk (*) in the table. In the ini file,
they are displayed as an encrypted string.
User Level
privilege
[WebUsers_UserLevel]
Defines the user's access level.
Monitor = (Default) Read-only user. This user can only view Web
pages and access to security-related pages is denied.
Administrator = Read/write privileges for all pages except security-
related pages including the Local Users table where this user has
read-only privileges.
Security Administrator = Full read/write privileges for all pages.
Master = Read/write privileges for all pages. This user also
functions as a security administrator.
Note:
At least one Security Administrator must exist. You cannot delete
the last remaining Security Administrator.
The first Master user can be added only by a Security
Administrator user.
Additional Master users can be added, edited and deleted only by
Master users.
If only one Master user exists, it can be deleted only by itself.
Master users can add, edit, and delete Security Administrators
(except the last Security Administrator).