MAINT MESSAGES 1/X
This page displays all FMS hardware related messages and all maintenance advisory messages which require
maintenance action. It is displayed only if any message related to internal failure are detected, otherwise MAINT
MSG prompt will not be displayed on the MESSAGE RECALL page and this page will not be available.
Display MAINT MESSAGE 1/1 page by pressing [INIT REF], <MSG RECALL> and <MAINT MSG>.
Maintenance messages are displayed in amber. Maintenance Advisory messages are displayed in white with
the latest identified by a leading asterisk *.
MSG RECALL [6L]: Access to the MESSAGE RECALL 1/X page. This prompt is displayed in amber when new
alert messages are displayed.
NOTE: Message(s) will re-appear at power up only if fault is still present.
When on-ground, the digit to the extreme right of each maintenance advisory message indicates which FMU is
reporting the message. No digit means that all FMUs are reporting the same message.
FMS1 MAINT MESSAGES 1/1
FMS
OP CHECKSUM FAILED
H/W RTC FAILED
BOOT CHECKSUM FAILED
FMS1 X-TALK FAILED 1
<MSG RECALL
FMS1 MAINT MESSAGES 1/1
OP CHECKSUM FAILED
H/W RTC FAILED
BOOT CHECKSUM FAILED
FMS1 X-TALK FAILED 1
<MSG RECALL