EasyManua.ls Logo

Esterline CMA-9000 - START-UP AND INITIALIZATION

Esterline CMA-9000
561 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATOR’S MANUAL
CMA-9000 FLIGHT MANAGEMENT SYSTEM
START-UP AND INITIALIZATION
1. Verify that all relevant circuit breakers are on.
2. Upon initial power-up, the FMS will test all the annunciators. After these tests, it displays the IDENT 1/2
page as the default power-up page.
1R
2R
3R
4R
5R
6R
FMS1 IDENT 1/2
NAV DATABASE ACTIVE
KLMWW0697
OCT10-NOV06/03
SECOND
KLMWW0697
NOV07-DEC04/03
OP PROGRAM CFG NO
614876-040 00777
CUSTOM DATABASE DATE
EC-RTEST MAR21/04
USER DATABASE DATE
EC-UDTEST MAR21/04
<SETUP POS INIT>
1L
2L
3L
4L
5L
6L
3. Adjust the intensity of the FMS display by pressing and holding the BRT key until a comfortable viewing
level is obtained.
Each depression of the BRT key alternately brightens or dims the display. On initial power up, or when a
time interval of more than 5 seconds has elapsed since the last time the [BRT] key was pressed, the first
press of this key will always increase brightness.
4. Verify the OP PROGRAM (software version) and CFG NO. (system configuration) against the Aircraft Flight
Manual Supplement.
If either software or configuration numbers are incorrect, maintenance action is required.
5. Verify the date of the active database cycle.
If all identification data is correct, system start up and initialization is complete.
Page 3-3
August 17, 2010
DRAFT

Table of Contents