OPERATOR’S MANUAL
CMA-9000 FLIGHT MANAGEMENT SYSTEM
MAINTENANCE ADVISORY MESSAGES
Maintenance advisory messages are messages that do not require immediate pilot action but that indicate a
particular equipment failure condition:
• Displayed in white on the MAINT MESSAGES page.
• Displayed on the scratchpad unless an associated collector message exists and is active (until
acknowledged).
• Lowest priority scratchpad messages (can be typed over and overwritten by any other message type).
• Unless otherwise noted, the FMS Master Caution is inactive (e.g. FMS is still functional) for all the
Maintenance Advisory messages.
• Collector messages are messages that combine several fault conditions into a single alert message. (e.g.
AIR DATA LOST combines ADC1 FAILED and ADC2 FAILED Maintenance Advisory messages).
MAINTENANCE
ADVISORY
MESSAGE
DESCRIPTION ACTION
ADC1 FAILED
ADC2 FAILED
Failure of the ADC receiver or the ADC
communication BUS.
Ensure that ADC is powered. Verify that ADC
operates normally.
Advise maintenance.
Refer to Section 15 of the Operator’s Manual
for operation with a failed TAS/Altitude input
if an alternate TAS/Altitude source is not
available.
ADC1 DEGRADED
ADC2 DEGRADED
ADC3 DEGRADED
Invalid data in ADC critical label list.
Acknowledge that the faulty ADCx is not used
by the FMS.
When the installation is permitting, perform a
manual reversion of ADC source.
Advise maintenance.
ADF1 FAILED
ADF2 FAILED
ADF receiver input failure
Tune ADF from another source.
When ADF receiver is no longer operational,
use other navigation aids.
AFCS1 FAILED
AFCS2 FAILED
AFCS input failure Check ARINC connection between AFCS
and FMS Equipment.
AUTO RESET
Upon an exceptional fault the FMS has
restarted.
The unit has detected a problem and has
attempted to restart. No action required
except to verify it is functioning as expected.
CAPT EFIS INPUT
FAILED
Failure of the Capt. EHSI or failure of the
Capt. EHSI communication bus.
Ensure that Capt EHSI is powered. Verify if
EHSI operates normally.
Map display available on F/O EHSI.
Advise maintenance.
CONC1 FAILED
CONC2 FAILED
Concentrator input failure
Loss of the CONCENTRATOR input alone
does not cause any adverse effect; the
specific equipment affected will be
annunciated directly.
Page E-23