Chapter 5 Information Settings and Display
5.3 Maintenance > show disk-error
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
650
show disk-error
This command displays the details of disk errors.
■ Syntax
■ Parameter
No parameters.
■ Output
■ Example(s)
show disk-error
# E Disk Status Port Media Drive Drive-Recovered SMART I/O Link Check-Code
# Location Error Error Error Error Timeout Error Error
# * CE-Disk#0 Rebuild/Copyback Port#0 0 0 0 0 0 0 0
# A B C Port#1 0 0 0 0 0 0 1
D E F G H I J K
A: An error Sign (*), it shows there are some errors of both ports.
B: Disk Number
C: Disk status
D: Disk Port Number
E: Media Error Count
F: Drive Error Count
G: Drive Recovered Error Count
H: SMART Event Count
I: I/O Timeout Count
J: Link Error Count
K: Check Code Error Count
The following example displays the disk error information:
CLI> show disk-error
E Disk Status Port Media Drive Drive-Recovered SMART I/O Link Check-Code
Location Error Error Error Error Timeout Error Error
* CE-Disk#0 Rebuild/Copyback Port#0 0 0 0 0 0 0 0
Port#1 0 0 0 0 0 0 1
* CE-Disk#1 Available(Predictive Failure) Port#0 2 0 0 1 0 0 0
Port#1 0 0 0 0 0 0 0
DE#4-Disk#0 Rebuild/Copyback Port#0 0 0 0 0 0 0 0
Port#1 0 0 0 0 0 0 0