EasyManua.ls Logo

Fujitsu PRIMERGY TX2540 M1

Fujitsu PRIMERGY TX2540 M1
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX2540 M1
Upgrade and Maintenance Manual 149
Hard disk drives / solid state drives
7.2.6 Removing 2.5-inch HDD / SSD modules
7.2.6.1 Preliminary steps
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS Utility (see "ServerView Suite RAID
Management" user guide and manuals of RAID controller).
V CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
Ê "Removing accessible drive and HDD bay covers" on page 58
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V CAUTION!
Removing an operational HDD module will result in
data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array will
not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger capacity.
I After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 102.

Table of Contents