TX2540 M1
Upgrade and Maintenance Manual 205
8Fans
Safety notes
V CAUTION!
Do not damage or modify internal cables or devices. Doing so may
cause a device failure, fire, or electric shock.
Devices and components inside the server remain hot after
shutdown. After shutting down the server, wait for hot components to
cool down before installing or removing internal options.
Circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. Always discharge static build-up
(e.g. by touching a grounded object) before handling electrostatic-
sensitive devices (ESDs).
Do not touch the circuitry on boards or soldered parts. Hold circuit
boards by their metallic areas or edges.
If devices are installed or disassembled using methods other than
those outlined in this chapter, the warranty will be invalidated.
For further information, please refer to chapter "Important
information" on page 33.
8.1 Basic information
The following fans are available:
three system fans included in a system fan holder
one rear fan (only available in a redundant power supply configuration)
I Additional fans in power supply units are integral parts of the power
supply units and cannot be replaced separately.