48 Upgrade and Maintenance Manual
TX2540 M1
Basic hardware procedures
4.2 Shutting down the server
V CAUTION!
For further safety information, please refer to chapter "Important
information" on page 33.
I This step is only required when upgrading or replacing non-hot plug
components.
Ê Inform the system administrator that the server will be shut down and put
offline.
Ê Terminate all applications.
Ê Perform the required procedures described in the preliminary steps of each
upgrade or maintenance task.
Ê Shut down the server.
I If the system is running an ACPI-compliant operating system,
pressing the On / Off button will perform a graceful shutdown.
Ê Switch on the ID indicator on the front and rear connector panels of the
server as described in section "Locating the defective server" on page 45.
4.3 Disconnecting the server from the mains
Figure 2: Removing the power cord from the cable tie
Ê Pull out on the locking lever on the cable tie (1) and loosen the loop (2).
Ê Disconnect the power cord from the PSU and remove it from the cable tie.