Ê "Switching on the server" on page 73
Ê Verify whether the backup data on the Chassis ID EPROM has been
restored to the system board as described in section "Verifying system
information backup / restore" on page 87.
Ê "Verifying the system time settings" on page 98
Ê Inform the customer about changed WWN and MAC addresses. For further
information, refer to section "Looking up changed MAC / WWN addresses"
on page 103.
Ê After replacing the system board in a server running Linux OS, update the
MAC address of the onboard network controller in the related NIC definition
file as described in section "Updating the NIC configuration file in a Linux
environment" on page 100.
Ê "Enabling SVOM boot watchdog functionality" on page 96
Ê "Enabling BitLocker functionality" on page 101
Ê Reconfigure your network settings in the operation system according to the
original configuration of the replaced controller (expansion card or onboard).
I Configuration of network settings should be performed by the
customer.
For further information, please refer to section "Note on network
settings recovery" on page 367.
Ê If applicable,"After replacing the system board" on page 106