Chapter 7 Keypad and Related Functions
7-2-2
â– Conditions for the function-specific display ([b037] = 01) and displayed parameters
Parameters displayed when conditions are met
Display when "2nd-motor
control [SET] (08)" is
assigned to any of the
input terminal functions
[SET] is assigned to any of
[C001] to [C007].
[F202], [F203], [A201] to [A204], [A220],
[A244], [A245], [A261], [A262], [A281],
[A282], [A292] to [A296], [b212],
[b213], [b221] to [b223], [C241],
[H202] to [H206]
Display when the control
mode for 1st-motor is
constant torque or
reduced torque of V/f
control
[A041] to [A043], [A046], [A047]
Display when the control
mode for 2nd-motor is
constant torque or
reduced torque of V/f
control
[SET] is assigned to any of
[C001] to [C007] and
[A244] = 00 or 01.
[A241] to [A243], [A246], [A247]
Display when the control
mode for 1st-motor/2nd-
motor is free V/f
[A044] = 02.
Or [SET] is assigned to any of
[C001] to [C007], and
[A244] = 02.
Display when the control
mode for 1st-motor is
sensorless vector control
[d009], [d010], [d012], [b040] to
[b046], [C054] to [C059], [H001],
[H005],
[H020] to [H024], [H030] to [H034],
[P033], [P034], [P036] to [P041]
Display when the control
mode for 2nd-motor is
sensorless vector control
[SET] is assigned to any of
[C001] to [C007] and
[A244] = 03.
[d009], [d010], [d012], [b040] to
[b046], [C054] to [C059], [H001],
[H205],
[H220] to [H224], [H230] to [H234],
[P033], [P034], [P036] to [P041]
Display when free
electronic thermal
function is used
[b013] = 02.
Or [SET] is assigned to any of
[C001] to [C007] and
[b213] = 02.
Display when DC braking
is used
[A051] =01 or 02.
Or "External DC braking [DB]
(07)" is assigned to any of
[C001] to [C007].
[d004], [d153], [d155],
[A072] to [A079], [A156], [A157],
[C044], [C052], [C053]
Display when curve
acceleration/deceleration
is used
[A097] = 01 to 04.
Or [A098] = 01 to 04.
[A131], [A132], [A150] to [A153]
Display when
instantaneous power
failure non-stop function
is used
Display when brake
control function is used
Display when overvoltage
suppression function
during deceleration is
used
Display when simple
positioning control is
used
[d008], [P004], [P011], [P012],
[P014] to [P017], [P026], [P027],
[P060] to [P073], [P075], [P077],
[P080] to [P083], [H050], [H051]
Display when EzSQ is
used
[d023] to [d027], [P100] to [P131]
Display when EzCOM is
used