Page #452 background imageLoading...
Page #452 background image
Chapter 18 List of Parameters/Modbus Coil/Register Numbers
18-2-19
18.2.5 C Parameter Group
Code
Name
Data range
Initial
value
Set
value
Change
during
running
Modbus communication
Page
Register No.
Data Range
Resolution
C001
Input terminal [1]
function
See "18.2.6 List of Intelligent
Input Terminal Functions"
[FW]
✓
1401h
0 to 91 /
255(no)
-
9-15-1
C002
Input terminal [2]
function
[RV]
✓
1402h
-
C003
Input terminal [3]
function
[CF1]/
[EXT]/
[CF1]
*1
✓
1403h
-
C004
Input terminal [4]
function
[CF2]/
[RS]/
[CF2]
*1
✓
1404h
-
C005
Input terminal [5]
function
[2CH]/
[CF1]/
[2CH]
*1
✓
1405h
-
C006
Input terminal [6]
function
[RS]/
[CF2]/
[RS]
*1
✓
1406h
-
C007
Input terminal [7]
function
[USP]/
[JG]/
[USP]
*1
✓
1407h
-
C011
Input terminal [1]
active state
00: NO: Normally Open
01: NC: Normally Closed
00
✓
140Bh
0 to 1
-
C012
Input terminal [2]
active state
00
✓
140Ch
-
C013
Input terminal [3]
active state
00
✓
140Dh
-
C014
Input terminal [4]
active state
00
✓
140Eh
-
C015
Input terminal [5]
active state
00
✓
140Fh
-
C016
Input terminal [6]
active state
00
✓
1410h
-
C017
Input terminal [7]
active state
00
✓
1411h
-
C021
Output terminal
[11] function
See "18.2.7 List of Intelligent
Output Terminal Functions"
[FA1]/
[RUN]/
[FA1]
*1
✓
1415h
0 to 63 /
255(no)
-
9-16-1
C022
Output terminal
[12] function
[RUN]/
[FA1]/
[RUN]
*1
✓
1416h
-
C026
Output terminal
[AL] function
[AL]
✓
141Ah
-
C027
[Ao2] Output
monitor selection
(PWM/ Pulse
output)
00: Output frequency
01: Output current
02: Output torque (Sensorless
vector control)
03: Digital output frequency
04: Output voltage
05: Input power
06: Electronic thermal load
ratio
07: LAD frequency
08: Digital current monitor
10: Cooling fin temperature
12: EzSQ general-purpose
analog output YA0
15: Pulse input monitor
16: Option
07
✓
141Bh
0 to 8, 10,
12, 15, 16
-
9-16-5
*
1. The default settings when initialize by setting 00/01/03 to "Initialize data selection [b085]".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi WJ C1 Series and is the answer not in the manual?

Hitachi WJ C1 Series Specifications

General IconGeneral
BrandHitachi
ModelWJ C1 Series
CategoryInverter
LanguageEnglish