Chapter 9  Inverter Functions 
9-7-18 
9.7.11 Switching Between Two Motors 
 
  How to drive two different motors with different settings? 
  How to store separate setting configurations for two different motors? 
  How to change between setting configurations for batch production? 
 
  Turn the "2nd-motor control [SET]" for the input terminal function on to change target 
parameters. This function makes it possible to switch between different parameter 
configurations to control two different types of motors. 
  The "2nd-motor control is selected [SETM] (60)" output terminal function turns on when the 
[SET] function is turned on. 
  Parameters in the 200s parameter number of function groups A, b, C, and H are the second 
control parameters. 
(Example)  The second control parameter corresponding to the "Frequency input source selection, 
1st-motor [A001]" is the "Frequency input source selection, 2nd-motor [A201]". 
 
 These parameters do not change, even when changing [SET] during inverter operation. In this 
case, parameters change after the output is cut off. 
 Please allow at least one second for changes to occur if you want to switch the [SET] terminal 
and immediately run operations. 
 
2nd-motor control [SET]: 
Turn this function on to switch to the second control 
parameter. 
2nd-motor control is selected [SETM]: 
After [SET] is turned on, switching to the second 
control parameter turns this signal on. 
 
 
◼ List of parameters switched by turning [SET] on/off 
Acceleration time 1 setting or monitor 
Deceleration time 1 setting or monitor 
Electronic thermal characteristics selection 
Frequency input source selection 
Overload restriction 1 mode selection 
RUN command input source selection 
Overload restriction 1 active level 
Overload restriction 1 action time 
Async. Motor constant selection 
Torque boost mode selection 
Manual torque boost value 
Async. Motor number of poles 
Manual torque boost peak speed 
Async. Motor speed response 
Async. Motor stabilization constant 
Automatic torque boost voltage compensation gain 
Automatic torque boost slip compensation gain 
Async. Motor constant R1 (auto-tuning data) 
Async. Motor constant R2 (auto-tuning data) 
Async. Motor constant L (auto-tuning data) 
Async. Motor constant I0 (auto-tuning data) 
Accel/Decel change trigger selection 
Async. Motor constant J (auto-tuning data) 
Accel1 to Accel2 frequency transition point 
Decel1 to Decel2 frequency transition point