EasyManuals Logo

Hitachi WJ C1 Series User Manual

Hitachi WJ C1 Series
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #444 background imageLoading...
Page #444 background image
Chapter 18 List of Parameters/Modbus Coil/Register Numbers
18-2-11
18.2.4 b Parameter Group
Code
Name
Data range
Initial
value
Set
value
Change
during
running
Modbus communication
Page
Register No.
Data Range
Resolution
b001
Restart mode
selection after
instantaneous
power failure/
undervoltage
error
00: Trip
01: 0Hz start
02: Restart with frequency
matching
03: Decelerate and stop with
frequency matching and
then trip
04: Active frequency matching
restart
00
✓
1301h
0 to 4
-
9-9-10
b002
Instantaneous
power failure/
undervoltage
allowed time
0.3 to 25.0 (s)
1.0
✓
1302h
3 to 250
0.1
b003
Retry wait time
after
instantaneous
power failure/
undervoltage
error
0.3 to 100.0 (s)
1.0
✓
1303h
3 to 1000
0.1
b004
Enable
instantaneous
power failure/
undervoltage
error while in
stop status
00: Disable
01: Enable
02: Disable at Stop/Decel.
Stop
00
✓
1304h
0 to 2
-
b005
Number of retries
after
instantaneous
power failure/
undervoltage
00: 16 times
01: Unlimited
00
✓
1305h
0 to 1
-
b007
Frequency
matching
minimum restart
frequency
0.00 to 590.00 (Hz)
0.00
✓
1307h (High)
1308h (Low)
0 to 59000
0.01
9-7-3
b008
Restart mode
selection after
overvoltage/
overcurrent error
00: Trip
01: 0Hz start
02: Restart with frequency
matching
03: Decelerate and stop with
frequency matching and
then trip
04: Active frequency matching
restart
00
✓
1309h
0 to 4
-
9-9-14
b010
Number of retries
after
overvoltage/
overcurrent
1 to 3 (times)
3
✓
130Bh
1 to 3
1
b011
Retry wait time
after
overvoltage/
overcurrent error
0.3 to 100.0 (s)
1.0
✓
130Ch
3 to 1000
0.1
b012
Electronic
thermal level,
1st-motor
(0.20 to 1.00) × Rated
current (A)
Rated
current
✓
130Dh
200 to 1000
0.1
(%)
*1
8-1-8
b212
Electronic
thermal level,
2nd-motor
Rated
current
✓
230Ch
0.1
(%)
*1
b013
Electronic
thermal
characteristic
selection, 1st-
motor
00: Reduced torque
01: Constant torque
02: Free setting
01
✓
130Eh
0 to 2
-
8-1-9
*1. 100% of the set value means the rated current of the WJ-C1.