Chapter 9 Inverter Functions
9-1-6
9.1.6 Operation by Communication Option Board
How to operate the inverter using communication option board?
To perform forward/reverse rotation and stop operation using the communication option board,
set the "RUN command input source selection [A002]
*1
" to "Option (04)". For details, refer to the
Guides for each communication option board.
Code
Item
Description
Data
[A002]
*1
RUN command input
source selection
Commands from the option board are used to start
and stop inverter operation.
04
*1. "2nd-motor control [SET]" target parameter. The second control parameter is also subject to setting.
For the inverter to start operation, a frequency command is required in addition to a RUN
command.
!