EasyManua.ls Logo

Hitachi WJ C1 Series

Hitachi WJ C1 Series
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 14 Safety Function STO
14-1-8
Operation of STO input discrepancy [FSC]
The [FSC] signal is deactivated when [b145] is set to 05 or 06 and the inverter is in trip or delay
ON/OFF of [ST1]/[ST2] is detected (-F** is displayed). The judgement cycle of the [FSC] signal is
10 ms. (If [b145] is not 05/06 and the inverter is not in trip, the [FSC] signal is ON.)
(e.g.) [b145] = 05
(e.g.) [b145] = 06
Close
Close
Close
Close
Close
Close
Close
Close
ON
ON
ON
ON
-F20
-S--
-F02
-S--
AL (Trip)
RS (Trip reset)
-F01
b146
b146
[FSC]
Keypad
display
[ST2]
[ST1]
ON
ON
Close
Close
Close
Close
Close
Close
ON
ON
ON
ON
-F20-
-S--
[FSC]
Keypad
display
[ST2]
[ST1]
-F02
ON
ON
AL (Trip)
RS (Trip reset)

Table of Contents

Related product manuals