Page #456 background image
Chapter 18 List of Parameters/Modbus Coil/Register Numbers
18-2-23
Code
Name
Data range
Initial
value
Set
value
Change
during
running
Modbus communication
Page
Register No.
Data Range
Resolution
C163
Input terminal [4]
response time
0 to 200 (× 2ms)
1
✓
14A7h
0 to 200
2
9-15-3
C164
Input terminal [5]
response time
0 to 200 (× 2ms)
1
✓
14A8h
0 to 200
2
C165
Input terminal [6]
response time
0 to 200 (× 2ms)
1
✓
14A9h
0 to 200
2
C166
Input terminal [7]
response time
0 to 200 (× 2ms)
1
✓
14AAh
0 to 200
2
C169
Multistage input
determination
time
0 to 200 (× 10ms)
0
✓
14ADh
0 to 200
10
9-2-7
C900
IRDY action
selection
*3
00: Before WJ200 Ver. 3.0
01: WJ200 Ver. 3.0 or later
01
✓
14CCh
0 to 1
-
-
C901
Overload signal
judgement cycle
selection
*3
00: 40 msec
01: 2 msec
00
✓
14F0h
0 to 1
-
-
C902
Overload signal
filter time
constant
0 to 9999 (ms)
300
✓
14F1h
0 to 9999
1
9-11-3
9-11-4
C903
Overload signal
hysteresis
*3
00.00 to 50.00 (%)
10.00
✓
14F2h
0000 to 5000
0.01
-
*3. This parameter is a dummy parameter. User settings are disabled. Data can be read and written by Modbus
communication, etc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi WJ C1 Series and is the answer not in the manual?

Hitachi WJ C1 Series Specifications

General IconGeneral
BrandHitachi
ModelWJ C1 Series
CategoryInverter
LanguageEnglish

Related product manuals