Wiring D2 Series Servo Drive User Manual
4-26 HIWIN MIKROSYSTEM CORP.
MD07UE01-2005
4.3.2 AC power wiring (three-phase)
It is recommended to use the three-phase filter of FN3025HL-20-7.
Figure4.3.2.1
Table4.3.2.1
FN3025HL-20-71 Filter
Maximum continuous operation voltage
3 x 520/300 Vac
Operation frequency
DC to 60 Hz
Rated current
10 to 50 A @50
°
C
mega-fabs
D2 Series drive
CN1
L1
L2
L3
L1C
L2C
NFB Filter
KM
KM
ON
OFF
Emergency
Stop
KM
SK
3-phase
200~240VAC
50/60Hz
Earth