208
keypad emits a signal sound and the power LED is switched off.
Now you can arm and disarm the alarm panel by means of the keypad.
Range test:
1. Enter the installation mode of the keypad (default: 0000 + *)
2. Open the alarm panel menu “Sensors” “Range” and press “Start.”
3. Press the * + 7.
4. The sensor and the signal strength should be indicated. The higher the indicated
number the better the reception (1-9).
5. To exit the installation mode, press the disarm button two times.
Please note:
If the signal strength at the place of installation is below 4, we advice to use a
wireless repeater, since it is normal that the signal strength may fluctuate for 2-3
points, thus, a signal loss is possible.
Changing the PIN code to switch between the different modes of the alarm panel:
You can change the PIN code in the web interface of the alarm panel. Open the menu
“Alarm system” “Pin codes” and change the existing PIN code or enter a new one.
Controlling the alarm panel by means of the keypad:
1. Arm the alarm panel:
PIN code (default 1234) + arm button (a long signal is emitted + the status
LED lights up).
2. Disarm the alarm panel:
PIN code (default 1234) + disarm button (two signals are emitted + the
status LED lights up blue).
3. Switch to home mode:
PIN code (default 1234) + home button and press 1, 2, or 3 to select the
corresponding home mode (three signals are emitted + the status LED flashes
red). If you do not press any number key after pressing the home button, the
alarm panel will switch to home mode 1.
Options in installer mode
Enter the installer PIN (default= 0000)and press *. The Power LED lights up orange.
Dual-key functions:
The keypad features pre-defined dual key commands that allow you
to trigger a fire, panic, or medical alarm without entering a PIN
code. To activate the dual key functions, please proceed as follows:
If you go to the menu “Sensors” “List” and the keypad, you can
define the dual key commands (1+3, 4+6, 7+9).
Activate dual key 1 + 3 panic alarm
Activate dual key 4 + 6 fire alarm
Activate dual key 7 + 9 medical alarm
Deactivate all dual key functions