53
but sends a notification according to your “Alarm system” “Report”
settings.
o Intruder alarm silent
If a sensor with this setting is triggered, the sirens do not sound an alarm,
but sends a notification according to your “Alarm system” “Report”
settings.
Execute home automation command
If the sensor changes its state, one of 16 home automation rules or scenarios can
be performed, which are defined in the Automation menu (“Smarthome”
“Automation” or “Smarthome” “Scenarios”).
All areas (sirens only)
o Older siren versions with DIP switches: If you want to assign an external
siren to both areas, make sure that switch SW1 of the respective siren is
set to ON! Then enable this option. Afterwards, make sure to set switch
SW1 back to OFF.
o Newer siren version without DIP switches:
Press the learn button of the siren.
LED 1 & 3 of the outdoor siren V2 light up. The indoor siren emits a
brief confirmation sound
Check “all areas” and click on “OK”
The outdoor siren V2 sounds a confirmation signal, LED 2 flashes
briefly. The indoor siren emits a confirmation beep.
Current measurement (only wireless power supply devices / relays)
This option allows you to display the power consumption of a power supply
device or relay in the GRID interface.
Deactivated: Activated:
Trigger mode (only power supply devices like in-wall relays and, light switches)
Activates the trigger mode of the selected devices, which is available in the
menu “Smarthome” “Wireless plugs” “Wireless plugs list”. If this function is
enabled, the device is activated briefly and then deactivated again.
Always on (only power supply devices)
If you want to activate a wireless power supply device or in-wall relay irrespective
of the alarm mode of the alarm panel, you can activate this setting. Afterwards,
you once need to activate the PSS device manually. Afterwards, you cannot
switch this off anymore.
Emergency button (only medical emergency controller + panic button)
Allows you to set what kind of alarm is triggered or which automation rule is
performed, when the sensor’s alarm button is pressed.