215575 100 Revision B
3.13 Unplugging the Header
Be sure to disengage the header drive before attempting to clear a plugged pick-up header.
1. Stop the forward movement of the combine and disengage the header.
2. Fully raise the hold-down.
3. Disengage the pick-up header’s draper drive.
IMPORTANT:
• To prevent damage to the feeder motor, do NOT engage the feeder reverser for more than five seconds if the
feeder and auger will not turn.
• To prevent damage to the hold-down rods, raise the hold-down assembly before reversing the header.
4. Run the feeder backwards using the reverse controls inside the combine cab to clear the plug.