215575 156 Revision B
4.9.4 Turning Accumulator Off – Gleaner
®®
R65/R66/R75/R76 and S Series
Activating the accumulator on a Gleaner
®
R65/R66/R75/R76 and non-S9 S series combine will negatively affect the speed
at which the AHHC system adjusts the height of the header. Turning the accumulator off will ensure good AHHC
performance.
$
Figure 4.108: Combine Accumulator ON/OFF Switch
A - Accumulator Lever (Off Position)
Refer to the combine operator’s manual for the proper
procedure for turning the accumulator off and on. For best
performance of the AHHC system, turn the feeder house
accumulator off.
4.9.5 Adjusting Header Raise/Lower Rate – Gleaner
®®
R65/R66/R75/R76 and S Series
The speed at which the header rises or falls on a Gleaner
®
R65/R66/R75/R76 and non-S9 S series combine can be adjusted
by opening or closing the height restrictor valves.
NOTE:
Refer to 4.10 Gleaner
®
S9 Series Combines, page 161 for information specific to Gleaner
®
S9 Series combines.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator’s manual for updated information.
AUTO HEADER HEIGHT CONTROL