1100 Matrix PRASAR UCS System Manual
• If you select Ethernet, in Destination IP Address, enter the IP Address of the remote Syslog Server.
Both IPv4 and IPv6 addresses are supported.
In Port, enter the port of the remote Syslog Server. Valid port range is: 514; 1025 to 65535.
• To configure Call Record Format for Incoming Calls, click SMDR Incoming Online Record Format to
expand.
• Configure the following Call Record Format parameters as required.
For each parameter explained briefly below, you can define the column position, field length (i.e. the
number of digits), the alignment (whether left aligned or right), and the filler characters, wherever required.
• Serial Number: This is the serial number generated for each call record. Serial numbers are generated
from 001 to 999. When serial number '999' is reached, the numbers roll over to 001.
When this field rolls over, it increments the increment counter.
• Increment Counter: It increments when the serial number counter rolls over. The Increment counter
starts from A, ending at Z, and then roll over back to A.
• Property Code: This is the property code, if required. This may be an abbreviation of the property
name.
• Connected Number: This is the extension number that answered the call. You can define the column
position and the field length for the extension number.
• Trunk Number: This is the number of the trunk on which the call was received.