INSTALLATION - ALPHA ONE DRIVES - 2A-990-823225--1  1096
9. Connect power steering fluid hoses to control
valve (large fitting first) as shown.
!
CAUTION
Route hoses exactly as shown below. This will
help avoid stress on the hose fittings and will
help avoid kinks in the hose.
IMPORTANT: Make hydraulic connections as
quickly as possible to prevent fluid leakage.
IMPORTANT: Be careful not to cross-thread or
over tighten fittings.
Earlier Style Control Valve: Torque large fitting to
20-25 lb. ft. (27-34 N·m) and small fitting to 96-108 lb.
in. (11-12 N·m).
72026
b
a
a - Large Fitting
b - Small Fitting
Later Style Control Valve: Torque both fittings to 23
lb. ft. (31 N·m).
73786
10. Connect battery cables to battery by FIRST con-
necting POSITIVE (+) battery cable (usually red)
to POSITIVE (+) battery terminal. Tighten clamp
securely. Then, connect NEGATIVE (–) battery
cable (usually black) to NEGATIVE (–) battery
terminal. Tighten clamp securely.
NOTE: Spray terminals with a battery connection
sealant to help retard corrosion.