Description Data
Certificate EtherNet IP specification
- ODVA file no. 10286
- Test date: 9/6/2005
- Vendor ID 90
- See also: www.odva.org
- Industry-compatible CE, UL, and cUL
Note:
The EtherNet/IP card is supported by PR 5410 firmware release 1.30 or higher.
The IP address and subnet mask are set under
- [Fieldbus parameters] (refer also to
Chapter 7.18.5 and 12.2)
The EDS file is stored on the CD supplied with the device (fieldbus directory of the
respective device). The current file is also available to download online:
http://www.minebea-intec.com
4.6.18.1 Controls on fieldbus card
③
NOTICE
The ③③ DIL switch settings will not be used.
Make sure that the switches 1…8 are set to position "OFF."
Settings are defined via
- [Fieldbus parameter].
4 Device installation X3 Process Indicator PR 5410
Minebea Intec EN-117