Each limit consists of a switch-on and a switch-off point for definition of a hysteresis. The
3 pairs of values must be entered according to the same principle. The limit values always
refer to the gross weight. For the SPM addresses for the limits, see Chapter 13.4.
NOTICE
The limit values of an xBPI weighing point are scale-specific.
The scale must be active when entering the limit values.
The scale and the unit must not be changed after configuration.
The following settings are required: [Weighingpoint/xBPI-Scale] - [Setup] -
[Configuration] - [Application settings] - [Number of units] "1 Weight"
Define the parameters for limits under
-[Limit parameter].
For the configuration the following order must be followed:
1. Define limits.
2. Define an action.
3. Determine a condition.
4. Save parameters.