[Net filling] with dosing signals "Coarse/Fine" procedure
Taring:
The current gross weight is saved as tare
weight, and the net weight starts at zero.
Coarse:
A coarse flow (coarse and fine) is batched
until the preset is reached.
Fine:
A fine flow is batched until the switch-off
point (overshoot) is reached.
Calming:
Time to wait during which the overshoot is
effective and scale vibrations may settle.
5
432
1
Weight
+Tolerance
-Tolerance
Set point
Preset
Overshoot
Time
Tolerance checking:
The weight is determined and checked
against the tolerance values.
8.4.1.2 Net decrease (B4)
The scale is automatically discharged up to the specified value. The other parameters and
the process correspond to the [Net filling] mode; see Chapter 8.4.1.1.
Net = gross - tare
Tare = gross
Sequence of [Net decrease] with dosing signals "coarse/fine"
Taring:
The current gross weight is saved as the ta-
re and the net weight starts at zero.
Coarse:
A coarse flow (coarse and fine) is batched
until the preset value is reached.
Fine:
A fine flow is batched until the switch-off
point (overshoot) is reached.
Calming:
Time to wait during which the overshoot is
effective and scale vibrations may settle.
5
432
1
Weight
+Tolerance
-Tolerance
Set point
Preset
Overshoot
Time
Gross
Tolerance checking:
The weight is determined and checked
against the tolerance values.