Bytes 0…63 Name Type of data Function
Byte 2 Bit 0: reset power failure (power
fail)
Bit 1: reset error
Bit 2: weights as DINT
Bit 3: zero
Bit 4: tare
Bit 5: reset tare
Bit 6: filling mode
Bit 7: read material from the
material table
BOOL Bit 0:
rising edge
Bit 1:
rising edge: resets the error flag and error
code.
Bit 2:
status-controlled:
Value: 0 = Real, 1 = DINT
Bit 3:
rising edge
Bit 4:
rising edge
Bit 5:
rising edge
Bit 6:
status-controlled: 0 = fill, 1 = empty
Bit 7:
rising edge: A valid material ID is required
in byte 3. Filling does not start.
This function can be used to display materi-
al parameters on external displays.
Byte 3 Material ID BYTE Value range: 1…10
Byte 4…7 Set point DINT/REAL Weight
Byte 8…11 Preset DINT/REAL Preset point for switching from coarse flow
to fine flow.
Byte 12…15 Material overshoot (OVS) DINT/REAL Weight
Byte 16…19 Calming time DINT [ms]
Byte 20…23 Tolerance above set point DINT/REAL Weight
Byte 24…27 Tolerance below set point DINT/REAL Weight
12.3.5.2 Read window EasyFill → PLC
The data required for monitoring and controlling filling does not fit in a 64-byte write
window. For this reason the system differentiates between system and material
parameters. The value of the first byte can be used to determine whether the data refers
to the system or the material.
12.3.5.2.1 System data
Before starting filling, a check must be carried out to ensure that the system is ready
(byte 3: bit 2).
The Dosing_Run bit is set once filling has successfully started.
Bytes 0…63 Name Type of data Function
Byte 0 TableSelect USINT Content of read data:
0 = system data, 1 = material data