Assign Alarm/AIS Settings 10-5
iPASOLINK EX Advanced: SET NETWORK AND SYSTEM PROVISIONING GGS-000547-01E
Figure 10-6 Alarm Severity Setting Option Window (Example: RF)
Table 10-2 Alarm Status Values (Severity Levels)
Parameter Value Description (Intended Condition)
(Alarm Item) Critical A service-affecting condition that requires an immediate corrective
action.
Major A service-affecting condition that requires an urgent corrective action.
Minor An existence of non-service-affecting failure that should take a
corrective action to prevent more serious service-affecting failure.
Warning A potential or impending service affecting failure. Action should be
taken to further diagnose (if necessary), and correct the problem in
order to prevent more serious service affecting failure.
Table 10-3 Alarm Severity Setting — RF
RF Alarm Item Default State Your Assignment
TX Power Major
RX Level Major
Table 10-4 Alarm Severity Setting — MODEM (1 of 2)
MODEM Alarm Item Default State Your Assignment
LOF Major
Frame ID Major
High BER Major
Low BER Minor
Early Warning Warning
RDI Warning
UAE Warning
AMBR Range Mismatch Major