5-40 CORRECTIVE MAINTENANCE
GGS-000548-01E iPASOLINK EX Advanced: OPERATION & MAINTENANCE
Equipment
This condition is not an alarm. The message indicates the state of PTP Radio Clock.
Equipment
This condition is not an alarm. The message indicates the selected Master to which
the PTP-BC function synchronizes.
Equipment
This condition is not an alarm. The message indicates the time when synchronizing
with Master using the PTP function. The indicated time does not show the date or
time of Management.
Equipment
This condition is not an alarm. The message indicates the quality level of the Timing
Clock.
MODEM
This condition indicates that RDI (Remote Defect Indication) signal is detected.
Procedure 5-26
1. Check if any alarm(s) occur(s) in the far-end NE. If any exist(s), correct it/them.
2. Retrieve the Current Status, and check if the RDI alarm is cleared. If the alarm is
not cleared, contact NEC for the further maintenance support.
This step ends the procedure.
PTP Radio Clock Status
PTP Source Status
PTP Sync. Time
Quality Level
RDI