10-4 Assign Alarm/AIS Settings
GGS-000547-01E iPASOLINK EX Advanced: SET NETWORK AND SYSTEM PROVISIONING
10.2 Alarm Severity Setting
Using the following procedure, alarm severity levels can be assigned to conditions
that iPASOLINK has.
Procedure 10-2
1. Launch and log in to WebLCT.
2. In the MENU frame on the left, expand Provisioning, then expand Alarm/AIS
Setting
to select Alarm Severity Setting. The Alarm Severity Setting window
appears.
3. Click the target object tab to select, and click the Modify tool button:
Figure 10-5 Alarm Severity Setting Window — RF Tab
Alarm Severity Setting
option window appears.
4. Assign the severity level by selecting the level from the Alarm Status drop-down
list:
click a tab
Modify tool button