CORRECTIVE MAINTENANCE 5-25
iPASOLINK EX Advanced: OPERATION & MAINTENANCE GGS-000548-01E
Equipment
This condition is not an alarm. The message indicates the current state of PTP logical
ports.
MODEM
This condition indicates that the system detects degradation of radio signals. (Early
Warning threshold detection.)
Procedure 5-5
1. Launch the WebLCT.
2. Display the Current Metering to check RX Level.
If the value is appropriate, replace the equipment.
If the value is inappropriate, proceed with the flowchart:
5.4 Trouble
Shooting Flow.
This step ends the procedure.
Equipment
This condition is not an alarm. The system reports that the equipment starts up, and
the cause to start up or reboot.
ETH
This condition indicates that the 10G Ethernet Port on the local NE fails.
Procedure 5-6
1. Check that the Ethernet Cable connected to the target port is appropriately
connected.
2. Retrieve the Current Status, and check if the ETH LF alarm is cleared.
3. Is ETH LF alarm cleared?
YES: This step ends the procedure.
NO: Replace the cable, then proceed to the next step.
Current Status
Early Warning
Equipment Start-up Status
ETH LF

Table of Contents