EasyManua.ls Logo

NEC iPASOLINK EX Advanced - Environmental Conditions; Humidity; Temperature; Power Line Requirements

NEC iPASOLINK EX Advanced
793 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-2 SYSTEM PERFORMANCES
GGS-000549-01E IPASOLINK EX ADVANCED: SPECIFICATION
3.2 Environmental Conditions
3.2.1 Temperature
3.2.2 Humidity
3.3 Power Line Requirements
3.3.1 DC IN
3.3.2 PoE
Condition Requirements
Operating (in windless condition) –33 to +45°C
(wind speed is 1 m/s) –33 to +50°C
Reference –33 to+40°C by ETSI EN 300 019-1-4
Class 4.1 in the EU market
Transportation –40 to +70°C (ETSI EN 300 019-1-2 Class 2.3)
Storage –25 to +55°C (ETSI EN 300 019-1-1 Class 1.2)
Condition Requirements
Operating Up to 100% all-weather (IP66)
Transportation Up to 100%
Storage Up to 100%
Condition Requirements
Input Voltage Range –48.0 V DC (–40.5 to –57.0 V DC)
ETSI EN 300 132-2
Connector molex® Mega-Fit Connector [172064-0004]
Condition Requirements
Input Voltage Range 41.0 to 57.0 V DC
LTPoE++ Compliant
Connector RJ-45 Connector

Table of Contents