5-24 CORRECTIVE MAINTENANCE
GGS-000548-01E iPASOLINK EX Advanced: OPERATION & MAINTENANCE
Equipment
This condition is not an alarm. The message indicates the clock class that the
opposing node uses.
Equipment
This condition is not an alarm. The message indicates the Clock ID that the opposing
node uses.
MODEM
This condition indicates that the Header Compression settings at two opposed sites
do not match, or an improper FPGA version that does not support the Header
Compression is set to enable these functions.
Procedure 5-4
1. Launch WebLCT.
2. Check and match the settings of VLAN Mode, Header Compression Mode, and
Payload Compression of alarmed MODEM and its opposed MODEM:
◆ WebLCT Menu Path:
Provisioning ➜ MODEM Function Setting
➜ MODEM Port Setting
3.
Retrieve the Current Status, and check if the Compression Setting Mismatch
alarm is cleared.
4. Is Compression Setting Mismatch alarm cleared?
YES: This step ends the procedure.
NO: Go to Step 5.
5. Check the FPGA Version of alarmed MODEM. If the improper FPGA is found,
fix it.
6. Retrieve the Current Status, and check if the Compression Setting Mismatch
alarm is cleared. If the alarm is not cleared, contact NEC for the further
maintenance support.
This step ends the procedure.
Clock Class
Clock ID
Compression Setting Mismatch